您的位置: 首页 > 2022年5月 第52卷 第3期 > 文字全文
2023年7月 第38卷 第7期11
目录

一种应用手机软件测量关节活动度的效度和信度研究

Validity and reliability of a mobile phone application for measuring joint ROM

来源期刊: 广州医药 | 42-45 发布时间:2022-07-01 收稿时间:2025/11/13 18:22:02 阅读量:61
作者:
关键词:
关节活动度测量关节活动范围智能手机
measurement of range of motionrange of motionsmart mobile phone
DOI:
10.3969/j.issn.1000-8535.2022.03.009
收稿时间:
2021-06-25 
修订日期:
 
接收日期:
 
引用总数:
2  
目的 研究应用手机软件(Goniometer Pro,G-pro)进行测量髋关节活动度(range of motion,ROM)的测量的信度和效度。方法 用量角器和苹果手机软件G-pro来测量髋关节ROM,共有12名受试者参加本次试验。测量者A应用量角器和G-pro来测量髋关节的屈曲角度,同时测量者B应用G-pro进行再次测量髋关节屈曲角度,24 h后测量者A在相同条件下应用G-pro再次测试髋关节屈曲角度。通过分析量角器与G-pro测量结果进行效度分析,通过比较测量者A与B,测量者A前后两次测量进行组间和组内信度研究。结果 在同一测量者量角器与G-pro测量值之间无显著性差异(P >0.05),测量者A用G-pro前后24 h前后测量受试者得出的差值也无显著性差异(P>0.05),测量者A、B用G-pro测量髋关节活动度的测量值无显著性差异(P>0.05)。结论 G-pro对于测量髋关节屈曲具有良好的信度和效度。
Objective To study the reliability and validity of measuring hip joint range of motion(ROM) with mobile APP (Goniometer Pro,G-pro). Methods The hip joint ROM was measured with a protractor and iPhone APP (G-pro), 12 subjects participated in this trial. Tester A used a protractor and iPhone APP (G-pro) to measure the flexion angle of the hip joint. Tester B used the mobile APP to measure the hip flexion angle again. Twenty-four hours later, tester A used the mobile APP to measure the hip flexion angle again under the same conditions. The validity was evaluated by analyzing the measurement results of protractor and mobile APP. The inter group and intra group reliability was studied by comparing the two measurements of tester A and tester B, and twice measurements of tester A. Results There was no significant difference between the measurements of protractor and iPhone APP by the same tester (P>0.05). There was no significant difference in the twice measurements of tester A using iPhone APP (P>0.05), and there was no significant difference in measurements of tester A and tester B using iPhone APP (P>0.05). Conclusions The iPhone APP (Goniometer Pro) has good reliability and validity in measuring hip ROM.
1、[12] POURAHMADI M, MOMENI E, MOHSENI N, et al. The reliability and concurrent validity of a new iPhone? application for measuring active lumbar spine flexion and extension range of motion in patients with low back pain[J]. Physiother Theory Pract, 2019,37(1):204-217.[12] POURAHMADI M, MOMENI E, MOHSENI N, et al. The reliability and concurrent validity of a new iPhone? application for measuring active lumbar spine flexion and extension range of motion in patients with low back pain[J]. Physiother Theory Pract, 2019,37(1):204-217.
2、[11] POURAHMADI M R, EBRAHIMI TAKAMJANI I, SARRAFZADEH J, et al. Reliability and concurrent validity of a new iPhone? goniometric application for measuring active wrist range of motion: a cross-sectional study in asymptomatic subjects[J]. J Anat, 2017,230(3):484-495.[11] POURAHMADI M R, EBRAHIMI TAKAMJANI I, SARRAFZADEH J, et al. Reliability and concurrent validity of a new iPhone? goniometric application for measuring active wrist range of motion: a cross-sectional study in asymptomatic subjects[J]. J Anat, 2017,230(3):484-495.
3、[10] POURAHMADI M R, TAGHIPOUR M, JANNATI E, et al. Reliability and validity of an iPhone? application for the measurement of lumbar spine flexion and extension range of motion[J].Peer J,2016,4(8):e2355.[10] POURAHMADI M R, TAGHIPOUR M, JANNATI E, et al. Reliability and validity of an iPhone? application for the measurement of lumbar spine flexion and extension range of motion[J].Peer J,2016,4(8):e2355.
4、 FUCHS S,SANDMANN C,GERDEMANN G,et al. Quality of life and clinical outcome in salvage revision total knee replacement:hinged vs total condylar design[J].Knee Surg Sports Traumatol Arthrosc,2004,12(2):140-143. FUCHS S,SANDMANN C,GERDEMANN G,et al. Quality of life and clinical outcome in salvage revision total knee replacement:hinged vs total condylar design[J].Knee Surg Sports Traumatol Arthrosc,2004,12(2):140-143.
5、 惠寒青, 张玲莉, 喻大力,等. 新型颈椎三维电子关节角度仪的效度及重复测试信度[J]. 中国康复理论与实践, 2015, 21(11):1329-1332. 惠寒青, 张玲莉, 喻大力,等. 新型颈椎三维电子关节角度仪的效度及重复测试信度[J]. 中国康复理论与实践, 2015, 21(11):1329-1332.
6、 魏显招, 祁敏. 髋关节屈曲运动及其测量方法研究进展[J]. 中国矫形外科杂志, 2010, 18(17):1443-1446. 魏显招, 祁敏. 髋关节屈曲运动及其测量方法研究进展[J]. 中国矫形外科杂志, 2010, 18(17):1443-1446.
7、 HUO Y, VINCKEN K L, van der HEIJDE D, et al. Automatic quantification of radiographic wrist joint space width of patients with rheumatoid arthritis[J]. IEEE Trans Biomed Eng,2017,64 (11):2695-2703. HUO Y, VINCKEN K L, van der HEIJDE D, et al. Automatic quantification of radiographic wrist joint space width of patients with rheumatoid arthritis[J]. IEEE Trans Biomed Eng,2017,64 (11):2695-2703.
8、 薛永泰,徐红旗. 关节活动度三种测量方法结果的一致性评价[J]. 吉林体育学院学报, 2019,35(2):69-74. 薛永泰,徐红旗. 关节活动度三种测量方法结果的一致性评价[J]. 吉林体育学院学报, 2019,35(2):69-74.
9、 王瑞, 李圣节, 李飞, 等. 运用四点法测量肘关节关节角度的效果探讨[J]. 中华保健医学杂志, 2018, 20(4):298-299. 王瑞, 李圣节, 李飞, 等. 运用四点法测量肘关节关节角度的效果探讨[J]. 中华保健医学杂志, 2018, 20(4):298-299.
10、 胡超, 葛云, 陈颖. 人体关节活动度测量系统[J]. 中国医学物理学杂志, 2016,33(1):34-38. 胡超, 葛云, 陈颖. 人体关节活动度测量系统[J]. 中国医学物理学杂志, 2016,33(1):34-38.
11、 李文浩, 葛云, 陈颖. 基于欧拉角的关节活动度测量系统[J]. 电子测量技术, 2016, 39(7):132-135. 李文浩, 葛云, 陈颖. 基于欧拉角的关节活动度测量系统[J]. 电子测量技术, 2016, 39(7):132-135.
12、 潘达德, 顾玉东, 侍德,等. 中华医学会手外科学会上肢部分功能评定试用标准[J]. 中华手外科杂志, 2000(3):4-9. 潘达德, 顾玉东, 侍德,等. 中华医学会手外科学会上肢部分功能评定试用标准[J]. 中华手外科杂志, 2000(3):4-9.
13、 严广斌. 关节活动度(Range of motion,ROM)[J]. 中华关节外科杂志(电子版), 2014,8(3):409. 严广斌. 关节活动度(Range of motion,ROM)[J]. 中华关节外科杂志(电子版), 2014,8(3):409.
1、张鑫.深刺八髎穴治疗脊髓损伤后下肢痉挛的临床研究[D].安徽中医药大学,2023.DOI:10.26922/d.cnki.ganzc.2023.000236. 张鑫.深刺八髎穴治疗脊髓损伤后下肢痉挛的临床研究[D].安徽中医药大学,2023.DOI:10.26922/d.cnki.ganzc.2023.000236.
2、王簌.两款智能手环监测不同运动项目心率的信效度研究[D].首都体育学院,2023.DOI:10.27340/d.cnki.gstxy.2023.000106. 王簌.两款智能手环监测不同运动项目心率的信效度研究[D].首都体育学院,2023.DOI:10.27340/d.cnki.gstxy.2023.000106.
上一篇
下一篇
出版者信息








《广州医药》公众号
目录