1、 中华医学会眼科学会角膜病学组.激光角膜屈光手术临床诊疗专家共识(2015年)[J]. 中华眼科杂志,2015,51(4):249-253. 中华医学会眼科学会角膜病学组.激光角膜屈光手术临床诊疗专家共识(2015年)[J]. 中华眼科杂志,2015,51(4):249-253.
2、 郭慧,顾宝文,杨旭,等.Pentacam 和Sirius地形图系统与超声测厚仪角膜厚度的对比研究[J]. 国际眼科杂志,2012,12(2):281-284. 郭慧,顾宝文,杨旭,等.Pentacam 和Sirius地形图系统与超声测厚仪角膜厚度的对比研究[J]. 国际眼科杂志,2012,12(2):281-284.
3、 李岩,成拾明,李国保,等.Visante-OCT、Sirius及A超测量中央角膜厚度的比较[J]. 华南国防医学杂志,2013,27(9):630-633. 李岩,成拾明,李国保,等.Visante-OCT、Sirius及A超测量中央角膜厚度的比较[J]. 华南国防医学杂志,2013,27(9):630-633.
4、 SIMSEK A,BILAK S,GüLER M, et al. Comparison of central corneal thickness measurements obtained by RTVue OCT, Lenstar,Sirius Topography,and Ultrasound Pachymetry in Healthy Subjects [J]. Semin Ophthalmol,2015,21:1-6. SIMSEK A,BILAK S,GüLER M, et al. Comparison of central corneal thickness measurements obtained by RTVue OCT, Lenstar,Sirius Topography,and Ultrasound Pachymetry in Healthy Subjects [J]. Semin Ophthalmol,2015,21:1-6.
5、 HO T, CHENG AC, RAO SK, et al. Central corneal thickness measurements using Orbscan II,Visante,ultrasound and Pentacam pachymetry after laser in situ keratomileusis for myopia [J]. J Cataract Refract Surg,2007,33(7):1177-1182. HO T, CHENG AC, RAO SK, et al. Central corneal thickness measurements using Orbscan II,Visante,ultrasound and Pentacam pachymetry after laser in situ keratomileusis for myopia [J]. J Cataract Refract Surg,2007,33(7):1177-1182.
6、 彭希,刘谊.角膜厚度的测量及其临床意义[J]. 临床眼科杂志,2013,21(2):182-187. 彭希,刘谊.角膜厚度的测量及其临床意义[J]. 临床眼科杂志,2013,21(2):182-187.
7、 DOORS M,CRUYSBERG LP, BERENDSCHOT TT, et al. Comparison of central corneal thickness and anterior chamber depth measurements using three imaging technologies in normal eyes and after phakic intraocular lens implantation [J]. Graefes Arch Clin Exp Ophthalmol,2009,247(8):1139-1146. DOORS M,CRUYSBERG LP, BERENDSCHOT TT, et al. Comparison of central corneal thickness and anterior chamber depth measurements using three imaging technologies in normal eyes and after phakic intraocular lens implantation [J]. Graefes Arch Clin Exp Ophthalmol,2009,247(8):1139-1146.
8、 ISKANDER NG, ANDERSON PENNO E, PETERS NT, et al. Accuracy of Orbscan pachmetry measurement and DHG ultrasound pachymetry in primary laser in situ keratomileusis and LASIK enhancement procedures [J]. J Cataract Refract Surg,2001,27(5): 681-685. ISKANDER NG, ANDERSON PENNO E, PETERS NT, et al. Accuracy of Orbscan pachmetry measurement and DHG ultrasound pachymetry in primary laser in situ keratomileusis and LASIK enhancement procedures [J]. J Cataract Refract Surg,2001,27(5): 681-685.