论著

CT增强延迟扫描技术在非小细胞肺癌术前诊断中的应用价值

The application value of CT enhanced delayed scanning in preoperative diagnosis of non-small cell lung cancer

:547-552
 
目的 探讨CT增强延迟扫描技术在非小细胞肺癌术前诊断中的应用价值。方法 对2021年5月—2024年5月商丘市第一人民医院收治的82例非小细胞肺癌手术治疗患者进行回顾性分析,将其分为观察组,另选取82例肺部良性肿瘤患者作为对照组,收集其术前CT增强延迟扫描结果,以术后病理诊断结果为金标准,分析CT增强延迟扫描技术在非小细胞肺癌术前诊断中的应用价值。并对比不同临床病理特征非小细胞肺癌患者CT增强延迟扫描的CT增强值,采用Spearman相关性分析法分析CT增强值与非小细胞肺癌病理特征的关系。结果 CT增强延迟扫描显示观察组患者分叶征(12.50% vs 53.57%)、内部空泡征数量(6.25% vs 39.29%)低于对照组(χ2=26.560、24.680,P<0.05),观察组患者边缘毛刺(56.25% vs 17.86%)、胸部凹陷征(59.38% vs 14.29%)、高于对照组(χ2=43.330、64.600,P<0.05);82例非小细胞肺癌通过CT增强延迟扫描共确诊79例,CT增强延迟扫描诊断对非小细胞肺癌的准确率为96.34%(79/82),与病理诊断结果100.00%对比差异无统计学意义(χ2=3.060,P=0.080);82例非小细胞肺癌平均CT增强值为(39.14±7.31),不同性别、年龄、肿瘤最大直径、淋巴结浸润情况患者CT增强值对比差异无统计学意义(P>0.05),不同病理类型[腺癌(43.75±7.15)vs 鳞癌(34.74±6.12)]、细胞分化程度[中、低分化(45.71±7.21)vs 高分化(32.81±5.11)]、临床分期[Ⅰ期(31.03±2.12)vs Ⅱ期(36.61±3.13)vs Ⅲa期(46.32±6.83)]患者、淋巴结转移[是(42.75±4.21)vs 否(35.77±8.13)]CT增强值对比差异有统计学意义(t/F=5.243、8.804、84.828、4.378,P<0.05);Spearman相关分析结果显示:病理类型、细胞分化程度、临床分期、淋巴结转移与非小细胞肺癌患者CT增强值呈正相关(r=0.431,P=0.021;r=0.511,P=0.009;r=0.586,P=0.005;r=0.579,P=0.008,P<0.05)。结论 CT增强延迟扫描技术对非小细胞肺癌术前确诊具有重要价值,其诊断准确率与病理诊断并无显著差异,且可通过CT增强延迟扫描技术确定患者CT增强值,从而为非小细胞肺癌患者术后病理特征判断提供参考。
Objective To explore the application value of CT enhanced delayed scanning in preoperative diagnosis of non-small cell lung cancer(NSCLC).Methods A retrospective analysis was conducted on 82 patients with NSCLC who underwent surgical treatment in a hospital from May 2021 to May 2024.They were included into an observation group and another 82 patients with benign lung tumors were included in the control group.The preoperative CT enhanced delayed scanning results were collected,and the postoperative pathological diagnosis was used as the “gold standard” to analyze the application value of CT enhanced delayed scanning in the preoperative diagnosis of NSCLC.And the CT enhancement values of delayed CT scans in NSCLC patients with different clinical and pathological features were compared,and Spearman correlation analysis was used to analyze the relationship between CT enhancement values and pathological features of NSCLC.Results CT enhanced delayed scanning showed that the number of lobular(12.50% vs 53.57%)and internal vacuolar signs(6.25% vs 39.29%)in the observation group was significantly lower than that in the control group(χ2=26.560,24.680,P<0.05),while the edge spicules(56.25% vs 17.86%)and chest depression signs(59.38% vs 14.29%)in the observation group were significantly higher than that in the control group(χ2=43.330,64.600,P<0.05).A total of 79 cases of 82 NSCLC were diagnosed by CT-enhanced delayed scan,and the accuracy of CT-enhanced delayed scan diagnosis for NSCLC was 96.34%(79/82),with no significant difference from the pathological diagnosis result of 100.00%(χ2=3.060,P=0.080).The average CT enhancement value of 82 NSCLC cases was(39.14±7.31).There was no significant difference in CT enhancement values among patients of different genders,ages,maximum tumor diameter,and lymph node infiltration(P>0.05).Patients with different pathological types [adenocarcinoma(43.75±7.15)vs squamous cell carcinoma(34.74±6.12)],degree of cell differentiation [moderate,and low differentiation(45.7±7.21)vs high differentiation(32.81±5.11)],clinical stage [I(31.03±2.12)vs II(36.61±3.13)vs IIIa(46.32±6.83)] and lymph node metastasis [yes(42.75±4.21),vs no(35.77±8.13)] CT enhancement had significant difference(t/F=5.243,8.804,84.828,4.378,P<0.05).The Spearman correlation analysis results showed that pathological type,degree of cell differentiation,clinical stage,lymph node metastasis were positively correlated with CT enhancement values in NSCLC patients(r=0.431,P=0.021;r=0.511,P=0.009;r=0.586,P=0.005;r=0.579,P=0.008).Conclusions CT enhanced delayed scanning has important value in preoperative diagnosis of NSCLC.Its diagnostic accuracy is not significantly different from pathological diagnosis,and the CT enhanced value of patients can be determined through CT enhanced delayed scanning,providing reference for postoperative pathological feature judgment of NSCLC patients.
论著

CT增强碘对比剂急性不良反应发生及影响因素分析

Analysis of the occurrence and influencing factors of acute adverse reactions of enhanced CT iodine contrast agents

:829-835
 
目的 探讨电子计算机断层扫描(CT)增强碘对比剂急性不良反应发生及影响因素分析。方法 选取天津市肿瘤医院空港医院2020年10月—2023年10月收治的100例行CT增强出现碘对比剂急性不良反应的患者进行回顾性分析,将其分为观察组,另选取同期在我院行CT增强检查未发生不良反应的100例患者作为对照组。分析观察组患者碘对比剂急性不良反应情况,对比两组患者临床资料及碘对比剂注射情况,以急性不良反应作为因变量(发生急性不良反应=1,未发生急性不良反应=0)纳入Logistic回归模型,分析CT增强碘对比剂急性不良反应发生的独立影响因素。结果 100例发生碘对比剂急性不良反应的患者中轻度65例(65.00%),中度34例(34.00%),重度1例(1.00%);观察组与对照组性别、年龄、体质指数(BMI)、高血压史、糖尿病史、心功能不全史、甲状腺功能亢进史、冠状动脉粥样硬化性心脏病史、碘对比剂使用史、食物过敏史对比差异无统计学意义(P>0.05),观察组与对照组哮喘史(9.00% vs 2.00%)、肾功能不全史(13.00% vs 3.00%)、碘对比剂不良反应发生史(21.00 % vs 2.00%)、花粉过敏史(12.00% vs 4.00%)、药物过敏史(26.00% vs 7.00%)及其他过敏史(10.00 % vs 2.00%),对比差异有统计学意义(χ2=4.710,P=0.030;χ2=6.790,P=0.009;χ2=17.740,P<0.001;χ2=4.350,P=0.037;χ2=13.100,P<0.001;χ2=5.670,P=0.017);观察组与对照组碘对比剂剂量对比差异无统计学意义(P>0.05),观察组与对照组碘对比剂注射速度(<3 mL/min为55.00% vs 69.00%;≥3 mL/min为45.00% vs 31.00%)、碘对比剂类型(碘克沙醇为34.00% vs 34.00%,碘佛醇为47.00% vs 30.00%,碘海醇为19.00% vs 36.00%)对比差异有统计学意义(χ2=4.160,P=0.041;χ2=9.010,P=0.011);肾功能不全史、碘对比剂不良反应发生史、药物过敏史、其他过敏史、碘对比剂注射速度为发生碘对比剂急性不良反应的影响因素(P<0.05)。结论 CT增强碘对比剂急性不良反应多以轻度为主,且以往合并肾功能不全、碘对比剂不良反应发生史、药物过敏史、其他过敏史、碘对比剂注射速度过高可能为碘对比剂不良反应发生的影响因素。
Objective To explore the occurrence and influencing factors of acute adverse reactions of iodine contrast agents in enhanced computed tomography(CT). Methods A retrospective analysis was conducted on 100 patients admitted to our hospital from October 2020 to October 2023 who experienced acute adverse reactions to iodine contrast agents during CT enhancement.They were divided into an observation group and another 100 patients who underwent CT enhancement examination in our hospital during the same period without any adverse reactions were selected as the control group.The acute adverse reactions of iodine contrast agent in the observation group of patients were analyzed,the clinical data and injection of iodine contrast agent between the two groups of patients were compared,and include acute adverse reactions as the dependent variable(occurrence of acute adverse reactions=1,absence of acute adverse reactions=0)was used in the Logistic regression model to analyze the independent influencing factors of acute adverse reactions of CT enhanced iodine contrast agent.Results Among the 100 patients who experienced acute adverse reactions to iodine contrast agents,65 were mild reactions,accounting for 65.00%,34 cases had were moderate reactions,accounting for 34.00%,and one cases had severe reactions,accounting for 1.00%.There was no significant difference between the observation group and the control group in gender,age,body mass index(BMI),history of hypertension,diabetes,heart dysfunction,hyperthyroidism,coronary heart disease,use of iodine contrast agent,and food allergy(P>0.05).The history of asthma(9.00% vs 2.00%),renal insufficiency(13.00% vs 3.00%),adverse reactions of iodine contrast(21.00 % vs 2.00%),pollen allergy(12.00% vs 4.00%),drug allergy(26.00% vs 7.00%)and other allergies(10.00 % vs 2.00%)were significantly different(χ2=4.710,P=0.030;χ2=6.790,P=0.009;χ2=17.740,P<0.001;χ2=4.350,P=0.037;χ2=13.100,P<0.001;χ2=5.670,P=0.017).There was no significant difference in the dosage of iodine contrast agent between the observation group and the control group(P>0.05).The injection rate of iodine contrast agent between the observation group and the control group(< 3 mL/min was 55.00% vs 69.00%;≥3 mL/min was 45.00% vs 31.00%),and the types of iodoxanol (iodoxanol[34.00% vs 34.00%],iodoxanol[47.00% vs 30.00%],iodohexanol[19.00% vs 36.00%]) were significantly different(χ2=4.160,P=0.041;χ2=9.010,P=0.011).History of renal insufficiency,adverse reactions to iodine contrast agents,drug allergies,other allergies,and injection speed of iodine contrast agents were independent risk factors for the occurrence of acute adverse reactions to iodine contrast agents(P<0.05).Conclusions Acute adverse reactions to iodinated contrast agents in CT enhancement are mostly mild.Previous history of renal insufficiency,history of adverse reactions to iodinated contrast agents,history of drug allergies,other allergic histories,and high injection speed of iodinated contrast agents may be influencing factors for the occurrence of adverse reactions to iodinated contrast agents.
论著

MSCT增强扫描期相及VOI的选择在基于影像组学方法预测原发性肝细胞癌微血管侵犯中的价值

The value of contrast-enhanced MSCT with phases and VOI strategies in the prediction of microvascular invasion in primary hepatocellular carcinoma based on radiomics

:36-43
 
目的 基于影像组学方法,探讨多层螺旋CT(MSCT)四期增强扫描单一/不同期相及不同容积感兴趣区(VOI)的选择,在术前预测原发性肝细胞癌(HCC)微血管侵犯(MVI)中的价值。方法 回顾性收集88例经手术病理证实为HCC并行术前MSCT四期增强扫描的患者,其中包括47例MVI阳性患者和41例MVI阴性患者。在MSCT增强扫描的动脉早期、动脉晚期、门静脉期及延迟期图像中手动逐层勾画肿瘤ROI,获得瘤体容积感兴趣区VOI(Vt),然后基于计算机自动膨胀算法将Vt外扩10 mm获得瘤体及瘤周VOI(Vt+Vp)。使用Pyradiomics软件分别从Vt和Vt+Vp中提取影像组学特征,随后采用15种特征选择方法和10种分类器构建150个预测模型,并通过十折交叉检验以验证模型的效能。使用准确度、敏感度、特异度、受试者工作特性曲线下面积(AUC)评估模型的效能,并比较性能最优的前三个预测模型。结果 MSCT四期增强扫描图像中预测HCC MVI状态的影像组学模型在门静脉期的表现优于其它期相及各期相的不同组合,其中最大的AUC值在Vt和Vt+Vp两种ROI中分别为0.768和0.782。此外,基于Vt+Vp的影像组学模型对MVI的预测效能优于基于Vt的影像组学模型,基于Vt+Vp性能最优的预测模型的AUC值、准确度、敏感度和特异度分别0.782、0.728、0.745和0.705。结论 采用影像组学方法术前无创性预测HCC MVI状态首选增强扫描的门静脉期,ROI首选瘤体联合瘤周10 mm区域。
Objective To investigate the value of single or different phases of contrast-enhanced multi-slice spiral CT(MSCT)in different volumetric regions of interest(ROI)to preoperatively predict the state of microvascular invasion in primary hepatocellular carcinoma(HCC)based on radiomics methods.Methods A total of 88 patients with HCC confirmed by surgical pathology who underwent preoperative MSCT quadruple-enhanced scan were retrospectively recruited,including 47 MVI-positive patients and 41 MVI-negative patients.The ROI was manually delineated slice-by-slice in the early arterial phase,late arterial phase,portal venous phase,and equilibrium phase of enhanced MSCT images to obtain the volume of tumor VOI(Vt),and then Vt was expanded by 10 mm through the computer expansion algorithm automatically to obtain the volume of tumor and peritumor(Vt+Vp).Pyradiomics software was used to extract radiomic features from Vt and Vt+Vp,followed by 150 discriminant models constructed with 150 feature selection methods and 10 classifiers,and then 10-fold cross-validation was used to evaluate the performance of these models.Using accuracy,sensitivity,specificity,area under the receiver operating characteristic curve(AUC)to assess model performance.The top three predictive models with the best performance were also compared.Results The radiomics model for predicting HCC MVI status in portal venous phase among quadruple-enhanced MSCT images outperformed other phases and different combinations of phases,achieving the highest AUC values of 0.768 and 0.782 in Vt and Vt+Vp respectively.In addition,the prediction performance of the radiomics model based on Vt+Vp was superior to models based on Vt.AUC value,accuracy,sensitivity,and specificity of the model with the best performance based on Vt+Vp were 0.782,0.728,0.745 and 0.705 respectively.Conclusions Radiomics models based on the portal venous phase of contrast-enhanced MSCT and tumor combined with the 10mm peritumoral area were more recommended to be employed to preoperative non-invasively predict the state of HCC MVI.
出版者信息








《广州医药》公众号